Three Position Pneumatic Actuator introduction
The three-stage pneumatic actuator is a special type of actuator, which can provide three-position operation modes of 0°, 45°, 90°, and 180°. The intermediate position is achieved by the mechanical brake produced by the movement of the two auxiliary pistons. The intermediate position is adjustable. For example, the actuator with 90° stroke can provide intermediate positions of 20°, 30°, 50°, 70° and so on.
Three Position Pneumatic Actuator Features
CE certificate and According with international Standards, such as NAMUR,ISO5211 and DIN.
Integrated Design with Stable Quality.
Dual Piston rack and Pinion Design with High Output Power.
Multi-position Indicator, On-site Visual Instruction.
E. Double stroke adjustment, +/- 4 ℃ can be adjusted in the switch position
F. All sliding parts of the three-stage pneumatic actuator adopt plastic bearing bushings to guide, keep the minimum friction and effectively reduce the wear.
Product | Three Position Pneumatic Actuator |
Structure | Three Position Pneumatic Actuator |
Rotary Angle | 0-90 Degree, 0-120 Degree, 0-180 Degree |
Air Supply Pressure | 2.5-8 Bar |
Actuator Body Material | Aluminum Alloy |
Surface Treatment | Hard Anode Oxidation |
Operating Temperature | Standard Temperature:-20℃ ~ 80℃
Low Temperature:-15℃ ~ 150℃ High Temperature:-35℃ ~ 80℃ |
Connection Standard | Air interface: NAMUR
Mounting Hole: ISO5211 & DIN3337(F03-F25) |
Application | Ball Valve, Butterfly Valve & Rotary Machines |
Cover Color | Blue, Orange, Black, Grey or Customized Color |
Three Position Pneumatic Actuator Operation Demonstration
Three Position Pneumatic Actuator Drawing and Dimension
Pneumatic Actuator FAQ:
Q1: Pneumatic Valve can’t Move ?
A1: Check the Solenoid Valve is normal or not;
Test the actuator separately with air supply;
Check the handle position.
Q2: Pneumatic Actuator with slow motion ?
A2: Check air supply is enough or not;
Test the Actuator Torque is ok or not for the valve;
Check Valve coil or other components are too tight or not;
Q3: Reply Devices without Signal ?
A3: Inspect and repair power circuit;
Adjust the cam to correct position;
Replace micro switches.